Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Braz. j. phys. ther. (Impr.) ; 12(6)Nov.-Dec. 2008. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-504883

ABSTRACT

INTRODUÇÃO: Em nossa sociedade, temos observado uma oferta cada vez maior de modelos, cores, estilos, altura e diversos tipos de salto. OBJETIVO: Avaliar se o uso de calçados de salto alto influencia nas alterações posturais com base em um conjunto de variáveis mensuradas por meio da fotogrametria computadorizada. MÉTODOS: Vinte indivíduos que utilizam salto alto com freqüência (grupo 1) e 20 indivíduos que utilizam salto alto esporadicamente (grupo 2) foram fotografados no plano frontal anterior e sagital em três momentos: a) sem utilização de calçado, b) utilizando salto agulha e c) utilizando salto plataforma, sendo estas fotografias aleatorizadas e analisadas por um experimentador cego por meio da fotogrametria. A análise estatística foi realizada a partir da análise de variância em esquema fatorial 2x3, ou seja, comparando-se a freqüência do uso de salto com o tipo de calçado, com 5 por cento de significância. RESULTADOS: Apenas o ângulo protrusão da cabeça apresentou diferença quando comparados grupo 1 e 2 (p<0,01). O efeito do tipo de calçado ocorreu na variável alinhamento do joelho direito, sendo que houve diferença apenas entre o sapato agulha e os pés descalços (p=0,03); também para a variável ângulo tibiotársico, o efeito esteve presente em todos os tipos de calçado. Os demais ângulos avaliados não apresentaram diferenças entre a freqüência no uso de salto e os outros tipos de sapato. CONCLUSÕES: A freqüência do uso de salto e o tipo de salto praticamente não modificam a postura estática avaliada pela fotogrametria.


INTRODUCTION: In our society, it is observed an increasing number of models, colors, styles, heights and types of high heels. OBJECTIVE: To evaluate whether the use of high heel shoes results in postural changes, based on a set of variables measured through computerized photogrammetry. METHODS: Twenty individuals who often used high heels (group 1) and 20 individuals who only used high heels sporadically (group 2) were photographed in the frontal and sagittal planes at three conditions: a) without using footwear; b) using stiletto heels; and c) using high platform heels. These photographs were randomized and analyzed by a blinded examiner, by means of photogrammetry. Statistical analysis was performed, using a 2x3 factorial analysis of variance to compare the frequency of high heel use with the type of shoe, at the 5 percent significance level. RESULTS: Only the head protrusion angle showed a difference between groups 1 and 2 (p<0.01). The effect of the type of shoe observed in the alignment of the right knee, which only showed a difference between stiletto heels and barefoot (p=0.03). For the tibiotarsal angle variable, the effect was also observed for all types of footwear. The other angles evaluated did not present any differences regarding the frequency of high heel use and the types of shoe. CONCLUSIONS: The frequency and type of high heel practically did not change the static posture evaluated by photogrammetry.

2.
Braz. j. phys. ther. (Impr.) ; 10(4): 435-439, out.-dez. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-448256

ABSTRACT

OBJETIVO: O propósito deste estudo foi avaliar a confiabilidade inter e intra-examinador da fotopodometria, bem como a confiabilidade intra-examinador da fotopodoscopia. MÉTODO: Foram fotografadas as impressões plantares de 30 indivíduos hígidos de ambos os sexos, com idade média de 21,0 ±1,32 anos, posicionados sobre um podoscópio, com os pés descalços, apoio bipodal e postura ortostática. A imagem da impressão plantar refletida no vidro desse aparelho foi capturada por meio de uma câmera fotográfica digital de 2.1 megapixels, posicionada sobre um tripé em frente ao mesmo. As imagens foram arquivadas e, em seguida, submetidas às análises inter e intra-examinador. Para verificar a confiabilidade intra-examinador da fotopodoscopia, após quatro semanas, toda a metodologia de captura e análise de novos podogramas dos mesmos indivíduos foi repetida. RESULTADOS: As análises inter e intra-examinador da fotopodometria apresentaram, respectivamente, ICC= 0,96 e ICC= 0,98. O ICC de confiabilidade intra-examinador da fotopodoscopia foi de 0,94. CONCLUSÃO: Conclui-se então que a fotopodometria é um recurso de análise quantitativa confiável, sendo também a fotopodoscopia um método de avaliação aplicável para análises clínicas e científicas, permitindo, assim, acompanhar a evolução de tratamentos fisioterapêuticos dos apoios plantares, mesmo levando-se em consideração as variabilidades intrínsecas e extrínsecas dos indivíduos.


OBJECTIVE: To evaluate the inter and intra-examiner reliability of photopodometry and the intra-examiner reliability of photopodoscopy. METHOD: Plantar prints from 30 healthy individuals of both sexes with mean age of 21.0 ± 1.32 years were photographed. These individuals were positioned on a podoscope with bare feet, bipedal support and orthostatic posture. The plantar print images reflected on the glass of this instrument were captured using a 2.1 megapixel digital photographic camera positioned on a tripod in front of the podoscope. The images were filed and subsequently subjected to inter and intra-examiner analysis. To verify the intra-examiner reliability of photopodoscopy, the whole procedure of podogram capture and analysis was repeated on the same individuals four weeks later. RESULTS: The intraclass correlation coefficients (ICC) for the inter and intra-examiner analyses on the photopodometry were, respectively, 0.96 and 0.98. The ICC for the intra-examiner reliability of the photopodometry was 0.94. CONCLUSION: Photopodometry is a reliable quantitative analysis method and photopodoscopy is an evaluation method applicable to clinical and scientific analyses. They therefore make it possible to follow up the evolution of physiotherapeutic treatment on plantar supports, despite the intrinsic and extrinsic variability between individuals.

3.
Braz. j. med. biol. res ; 39(12): 1643-1649, Dec. 2006. graf, tab
Article in English | LILACS | ID: lil-439689

ABSTRACT

The objective of the present study was to determine the impact of acute short-term exposure to air pollution on the cardiorespiratory performance of military fireman living and working in the city of Guarujá, São Paulo, Brazil. Twenty-five healthy non-smoking firemen aged 24 to 45 years had about 1 h of exposure to low and high levels of air pollution. The tests consisted of two phases: phase A, in Bertioga, a town with low levels of air pollution, and phase B, in Cubatão, a polluted town, with a 7-day interval between phases. The volunteers remained in the cities (Bertioga/Cubatão) only for the time required to perform the tests. Cumulative load 10 ± 2 min-long exertion tests were performed on a treadmill, consisting of a 2-min stage at a load of 7 km/h, followed by increasing exertion of 1 km h-1 min-1 until the maximum individual limit. There were statistically significant differences (P < 0.05) in anaerobic threshold (AT) between Cubatão (35.04 ± 4.91 mL kg-1 min-1) and Bertioga (36.98 ± 5.62 mL kg-1 min-1; P = 0.01), in the heart rate at AT (AT HR; Cubatão 152.08 ± 14.86 bpm, Bertioga 157.44 ± 13.64 bpm; P = 0.001), and in percent maximal oxygen consumption at AT (AT percentVO2max; Cubatão 64.56 ± 6.55 percent, Bertioga 67.40 ± 5.35 percent; P = 0.03). However, there were no differences in VO2max, maximal heart rate or velocity at AT (ATvel) observed in firemen between towns. The acute exposure to pollutants in Cubatão, SP, caused a significant reduction in the performance at submaximal levels of physical exertion.


Subject(s)
Humans , Male , Adult , Middle Aged , Air Pollution/adverse effects , Environmental Exposure/adverse effects , Physical Exertion , Brazil , Exercise Test , Heart Rate/drug effects , Military Personnel , Maximal Voluntary Ventilation/drug effects , Oxygen Consumption/drug effects , Respiratory Function Tests/statistics & numerical data
4.
Braz. j. phys. ther. (Impr.) ; 10(1): 113-119, jan.-mar. 2006.
Article in Portuguese | LILACS | ID: lil-433027

ABSTRACT

Os efeitos da irradiacao ultra-sonica teraputica na regeneracao de nervos perifericos nao sao ainda bem conhecidos, particularmente no que se refere a recupercao funcional. Por outro lado o metodo da avaliacao da impressao da pegada do rato para medida do Indice Funcional do ciatico (IFC) ja esta bem sistematizado, mostrando streita correlacao com a regeneracao do nervo ciatico de ratos submetido a esmagamento ontrolado. Material e metodos: foram empregados 20 ratos da linhagem Wistar com peso corporal medio de 300g, divididos em dois grupos conforme o tipo de procedimento realizado: 1) somente esmagamento (n=10); 2)esmagamento e irradiacao com ultra-som (n=10). Sob anestesia geral, o nervo ciatico era exposto na coxa direita do animal e esmagado com um dispositivo especialmente confeccionado para essa finalidade, com uma carga fixa de 15 kg por 10minutos, num segmento de 5 mm proximal a sua bifurcacao. A irradiacao ultra-sonica pulsada de baixa intensidade (1:5, 0,4w/cm2, 1 MHz, duracao 2 minutos) era iniciada ja no rpimeiro dia pos-operatorio e realizada por dez dias consecutivos. As impressoes das pegadas dos animais, obtidas semanalmente, da primeira a terceira semana pos-operatoria em passarela especifica para essa finalidade, foram avaliadas por meio de um programa de computador igualmente especifico, segundo meto pre-existente ja testado em trabalhos anteriores, com calculo automatico do IFC. Resultados: o IFC aumentou progressivamente nos dois grupos, passando no Grupo 2 de 101 na primeira semana, para 59,21 na segunda e 26,68 na terceira, o que significou uma melhora de 73 por cento entre a primeira e a ultima medida. No grupo 1, o IFC subiu de -98,2 na primeira semana para -79,5 na segunda e -44 na terceira, o que significa uma melhora de 55 por cento entre a primeira medida e a ultima. As diferencas entre os grupos foram significativas no 14o. dia e no 21o. dia (p=0,02 e p=0,02, respectivamente). Conclusao: o ultra-som terapeutico de baixa intensidade acelerou a regeneracao do nervo ciatico do rato, demonstravel com maior significancia no 21o. dia pos-operatorio


Subject(s)
Sciatic Nerve , Peripheral Nerves , Rats, Wistar , Nerve Regeneration/physiology , Ultrasonics
SELECTION OF CITATIONS
SEARCH DETAIL